Transportación y centricidad en conductos curvos con ProTaper Next y PathFile / Transportation and Centering in Curved Canals with ProTaper Next and PathFile
Date
2015-12-30Authors
Escobar Ocampo, Andrés; Universidad Santo Tomás, Universidad El Bosque, BogotáHenao Bedoya, Adriana; Universidad Santo Tomás. Bogotá
Saavedra Amaya, Jeison; Universidad Santo Tomás, Bogotá
Serpa Vélez, María Fernanda; Universidad Santo Tomás, Bogotá
Gutiérrez Barreto, Javier; Universidad Santo Tomás, Bogotá
Publisher
Editorial Pontificia Universidad Javeriana
Type
Artículo de revista
ISSN
2027-3444
0120-4319
COAR
Artículo de revistaShare this record
Citación
Metadata
Show full item recordResumen
RESUMEN. Antecedentes: El sistema ProTaper Next, cuyos instrumentos mecanizados tienen un movimiento continuo con secciones trasversales excéntricas, producen un movimiento serpenteante que podría no mantener centrado el conducto radicular. Objetivo: Evaluar la transportación y la centricidad del sistema ProTaper Next con y sin el sistema PathFile, en conductos radiculares con curvatura moderada y evaluados por medio de tomografía volumétrica de rayo de cono. Métodos: Se tomaron 67 conductos radiculares de molares superiores con curvaturas moderadas de 10-20º. Se almacenaron en formalina al 10%, se seccionaron y decoronaron, y luego se dividieron en dos grupos de estudio de acuerdo con su instrumentación: ProTaper Next con y sin PathFile. Se tomaron tomografías de rayo de cono antes y después de la instrumentación. El análisis de las imágenes se realizó con el programa OsiriX, que evaluó la centricidad y la transportación de los tercios coronal, medio y apical en sentido vestibulolingual y mesodistal, a través de la superposición de imágenes antes y después de la tomografía. Resultados: Los grupos evaluados mantuvieron la centricidad sin transportar el conducto en sentido vestíbulopalatino y mesodistal en los tres tercios, sin presentar diferencias estadísticamente significativas (p<0,05). Conclusiones: Las limas rotatorias ProTaper Next no producen pérdida de centricidad ni transportación en ninguno de los tercios durante la preparación de conductos vestibulares de molares superiores con curvaturas moderadas. La instrumentación de conductos con ProTaper Next, con o sin las limas PathFile, no influye en la centricidad y transportación del conducto. ABSTRACT. Background: Rotary instruments of the ProTaper Next System have a continuous motion and an off-centered rectangular cross section that gives the files a unique snake-like swaggering movement. There are doubts if the system is able to maintain root canals in a centered position. Objective: To evaluate the transportation and centering ability of ProTaper Next System with and without PathFile, in root canals with moderate curvature, and evaluated by cone beam volumetric positron. Methods: The sample consisted of 67 molar root canals with moderate curvatures. The specimens were stored in 10 % formalin, later sectioned and uncrowned, and analyzed through cone beam scans before and after instrumentation using ProTaper Next. Specimens were assigned into two groups: with and without PathFile. The image analysis was performed using the OsiriX software, which allowed evaluating the centering ability and transportation of middle, apical and coronal thirds, in the lingual-buccal and mesio-distal direction, through image overlapping before and after scan. Results: The groups maintained centering ability without transporting the root canals through a buccal-palatal and mesio-distal direction in the coronal, middle and apical thirds. There were not statistically significant differences between groups based on centering ability and transportation (p<0.05). Conclusions: Root canal instrumentation with ProTaper Next, with or without glide path performed with PathFile™, does not affect centering ability or root canal transportation.
Keywords
endodonciacentricidad, PathFile; preparación del conducto radicular; ProTaper Next; sistemas rotatorios; transportación
Link to the resource
http://revistas.javeriana.edu.co/index.php/revUnivOdontologica/article/view/16143
Google Analytics Statistics
Collections
- Universitas Odontologica [339]
Except where otherwise noted, this item's license is described as Atribución-NoComercial-SinDerivadas 4.0 Internacional
Related items
Showing items related by title, author, creator and subject.
-
Mulheres ciganas: medo, relações intergrupais e confrontos identitários
Bonomo, Mariana; Universidade Federal do Espírito Santo; de Souza, Lídio; Universidade Federal do Espírito Santo; Araujo Trindade, Zeidi; Universidade Federal do Espírito Santo; Davel Canal, Fabiana; Universidade Federal do Espírito Santo; Alves Brasil, Julia; Universidade Federal do Espírito Santo; Mota do Livramento, André; Universidade Federal do Espírito Santo; da Silva Milani Patrocínio, Ana Paula; Universidade Federal do Espírito Santo (Pontificia Universidad Javeriana, 2010-08-24)Através da Teoria da Identidade Social buscou-se conhecer os estereótipos presentes no imaginário rural associados ao grupo cigano, bem como os sentimentos associados a esta etnia. Foram entrevistadas 10 mulheres rurais, ... -
Construindo o estado da arte da historia urbana na Colômbia: o caso Bogotá
Rueda Cáceres, Liliana; Docente investigadora en la Facultad de Arquitectura de la Universidad Santo Tomás de Bucaramanga.; Plata Quezada, William Elvis; Profesor asociado de la Escuela de Historia de la Universidad Industrial de Santander. (Instituto Carlos Arbeláez Camacho para el patrimonio arquitectónico y urbano, 2017-03-15)Este artículo es resultado de una investigación en historia urbana que indagó específicamente sobre un hecho puntual ocurrido en la Bogotá de 1939, la demolición del antiguo convento de Santo Domingo. Trabajo que abrió una ...Este artigo é o resultado de uma pesquisa em história urbana que investigou especificamente sobre um único fato ocorrido na Bogotá de 1939, a demolição do antigo convento de Santo Domingo. Trabalho que abriu uma porta ... -
Eficiencia del proceso de esterilización de las limas primarias WaveOne® / Effectiveness of Sterilization Process of Primary WaveOne® Files
Gutiérrez Barreto, Javier Fernando; Universidad Santo Tomás. Bogotá, Colombia; Castañeda Laborde, Claudia Marcela; Universidad Santo Tomás. Bogotá, Colombia; León Zuluaga, Victoria; Universidad Santo Tomás. Bogotá, Colombia.; Ortiz Andrade, Mayrim; Universidad Santo Tomás. Bogotá, Colombia (Editorial Pontificia Universidad Javeriana, 2015-12-30)RESUMEN. Antecedentes: Es importante en la práctica clínica que los instrumentos rotatorios usados estén estériles para evitar infecciones cruzadas. Objetivo: Evaluar la efectividad del proceso de esterilización de las ...