Mostrar el registro sencillo del registro

dc.rights.licenceAtribución-NoComercial 4.0 Internacional*
dc.contributor.authorRosenthal, Victor Daniel
dc.contributor.authorMaki, Dennis George
dc.contributor.authorSalomao, Reinaldo
dc.contributor.authorMoreno, Carlos Alvarez
dc.contributor.authorMehta, Yatin
dc.contributor.authorHiguera, Francisco
dc.contributor.authorCuellar, Luis E.
dc.contributor.authorArikan, Ozay Akan
dc.contributor.authorAbouqal, Rédouane
dc.contributor.authorLeblebicioglu, Hakan
dc.contributor.authorÁlvarez Moreno, Carlos Arturo
dc.contributor.authorInternational Nosocomial Infection Control Consortium
dc.date.accessioned2020-09-10T23:45:34Z
dc.date.available2020-09-10T23:45:34Z
dc.date.created2006
dc.identifier.issn0003-4819 / 1539-3704 (Electrónico)spa
dc.identifier.urihttp://hdl.handle.net/10554/51047
dc.formatPDFspa
dc.format.mimetypeapplication/pdfspa
dc.languageInglésspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.sourceAnnals of Internal Medicine; Vol. 145 Núm. 8 (2006)spa
dc.titleDevice-associated nosocomial infections in 55 intensive care units of 8 developing countriesspa
dc.typeinfo:eu-repo/semantics/article
dc.type.hasversionhttp://purl.org/coar/version/c_ab4af688f83e57aa
dc.description.quartilewosQ1spa
dc.description.quartilescopusQ1spa
dc.identifier.doihttps://doi.org/10.7326/0003-4819-145-8-200610170-00007spa
dc.description.paginas582-91spa
dc.format.soportePapel / Electrónicospa
dc.description.abstractenglishBackground: Health care-associated infections from invasive medical devices in the intensive care unit (ICU) are a major threat to patient safety. Most published studies of ICU-acquired infections have come from industrialized western countries. In a Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance (NNIS) System report, the U.S. pooled mean rates of central venous catheter (CVC)-related bloodstream infections, ventilator-associated pneumonia, and catheter-associated urinary tract infections were 4.0 per 1000 CVC days, 5.4 per 1000 mechanical ventilator days, and 3.9 per Foley catheter days, respectively. Objective: To ascertain the incidence of device-associated infections in the ICUs of developing countries. Design: Multicenter, prospective cohort surveillance of device-associated infection by using the CDC NNIS System definitions. Setting: 55 ICUs of 46 hospitals in Argentina, Brazil, Colombia, India, Mexico, Morocco, Peru, and Turkey that are members of the International Nosocomial Infection Control Consortium (INICC). Measurements: Rates of device-associated infection per 100 patients and per 1000 device days. Results: During 2002-2005, 21,069 patients who were hospitalized in ICUs for an aggregate 137,740 days acquired 3095 device-associated infections for an overall rate of 14.7% or 22.5 infections per 1000 ICU days. Ventilator-associated pneumonia posed the greatest risk (41% of all device-associated infections or 24.1 cases [range, 10.0 to 52.7 cases] per 1000 ventilator days), followed by CVC-related bloodstream infections (30% of all device-associated infections or 12.5 cases [range, 7.8 to 18.5 cases] per 1000 catheter days) and catheter-associated urinary tract infections (29% of all device-associated infections or 8.9 cases [range, 1.7 to 12.8 cases] per 1000 catheter days). Notably, 84% of Staphylococcus aureus infections were caused by methicillin-resistant strains, 51% of Enterobacteriaceae isolates were resistant to ceftriaxone, and 59% of Pseudomonas aeruginosa isolates were resistant to fluoroquinolones. The crude mortality rate for patients with device-associated infections ranged from 35.2% (for CVC-associated bloodstream infection) to 44.9% (for ventilator-associated pneumonia). Limitations: These initial data are not adequate to represent any entire country, and likely variations in the efficiency of surveillance and institutional resources may have affected the rates that were detected. Conclusions: Device-associated infections in the ICUs of these developing countries pose greater threats to patient safety than in U.S. ICUs. Active infection control programs that perform surveillance of infection and implement guidelines for prevention can improve patient safety and must become a priority in every country.spa
dc.type.localArtículo de revistaspa
dc.contributor.corporatenamePontificia Universidad Javeriana. Facultad de Medicina. Departamento de Medicina Interna. Grupo de Investigación en Enfermedades Infecciosas HUSI - PUJ


Ficheros en el registro

Thumbnail

Este registro aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del registro

Atribución-NoComercial 4.0 Internacional
Excepto si se señala otra cosa, la licencia del registro se describe como Atribución-NoComercial 4.0 Internacional