Impacto del ejercicio en la glucosa en pacientes con diabetes tipo 1: usuarios de sistema híbrido de asa cerrada con uso de objetivo temporal
View/ Open
Date
2022-08-09Authors
Gomez-Medina, Ana MariaHenao-Carrillo, Diana Cristina
Robledo, Sofia
Buendia, Richard
Jaramillo, Pablo
Muñoz, Óscar
Corporate Author(s)
Pontificia Universidad Javeriana. Facultad de Medicina. Departamento de Medicina Interna. Endocrinología
Pontificia Universidad Javeriana. Facultad de Medicina. Departamento de Medicina Interna. Medicina Interna
Type
Artículo de revista
ISSN
2389-9786 / 2805-5853 (Electrónico)
COAR
Artículo de revistaShare this record
Citación
Metadata
Show full item record
PDF documents
English Title
Impact of exercise on glucose in patients with type 1 diabetes who use a hybrid closed-loop system with the use of a temporary objectiveResumen
Contexto: el consenso sobre el manejo del ejercicio para los pacientes con diabetes tipo 1 (DM1) no incluye recomendaciones para pacientes usuarios de sistemas híbridos de asa cerrada (SHAC). Objetivo: describir en pacientes con DM1, usuarios de SHAC con uso de objetivo temporal, el comportamiento de la glucosa intersticial durante ejercicio aeróbico (EA) y de resistencia (ER). Metodología: estudio piloto descriptivo en el cual se incluyeron pacientes mayores de 18 años tratados con SHAC. Se registraron datos demográficos basales y se programaron sesiones de actividad física de EA de intensidad moderada y ER de acuerdo con las recomendaciones del consenso. En ambas sesiones se indicó uso del objetivo temporal 60 minutos antes y medir la glucosa capilar durante la actividad física (basal, 15, 30, 45 y 60 minutos). Al finalizar las sesiones de ejercicio se descargaron los datos del dispositivo. Resultados: se incluyeron 10 pacientes (80 % mujeres, edad promedio 41,1 ± 11,8 años) con TIR entre 70-180 mg/dl > 90 %. Durante el EA, el promedio de glucosa basal, 15, 13, 45 y 60 minutos fue de 147,1 ± 24,1 mg/dl, 131,4 ± 15,5 mg/dl, 131,4 ± 15,5 mg/dl, 107,9 ± 17 mg/dl y 101,3 ± 19,5 mg/dl, p < 0,05, respectivamente. Durante el ER no se observaron cambios significativos con respecto a la glucosa basal y 36 horas posterior a la actividad física se presentaron 2,75 eventos de hipoglucemia nivel 1, sin hipoglucemia severa.
Conclusiones: el EA disminuye los niveles de glucosa de forma temprana y significativa, mientras que en el ER los niveles de glucosa permanecen estables. Los datos reportados en este estudio sugieren que el uso de SCHA es seguro si se siguen las pautas del consenso y se programa el objetivo temporal.
Abstract
Introduction: The consensus on exercise management for patients with type 1 diabetes (T1D) does not include recommendations for patients using hybrid closed loop (HCL) systems. Objective: to describe the behavior of interstitial glucose during aerobic exercise (AE) and resistance exercise (RE) in patients with T1D users of HCL systems.
Methodology: Observational pilot study. Patients >18 years of age treated with HCL system were included. Baseline demographic data was recorded and moderate intensity AE and RE physical activity sessions were scheduled according to the consensus recommendations. In both sessions, it was indicated to use a temporary goal 60 minutes before and to measure capillary glucose during physical activity (baseline, 15, 30, 45 and 60 minutes). At the end of the exercise sessions, the data was downloaded from the device.
Results: 10 patients were included (80% women, mean age 41.1±11.8 years) with an TIR between 70-180 mg/dl >90%. During EA the mean basal glucose, 15,13,45 and 60 minutes were 147.1±24.1mg/dl, 131.4±15.5mg/dl, 131.4±15.5mg/dl, 107.9±17mg/dl and 101.3±19.5mg/dl, p <0.05, respectively. During the ER no significant changes were observed with respect to basal glucose. 36 hours after physical activity, there were 2.75 level 1 hypoglycemic events, without severe hypoglycemia.
Conclusions: EA lowers glucose levels early and significantly, while ER glucose levels remain stable. The data reported in this study suggest that the use of SCHA following the consensus guidelines and programming the time goal is safe.
Keywords
Ejercicio aeróbicoEjercicio de resistencia
Administración automática de insulina
Sistema híbrido de asa cerrada
Tiempo en rango
Hipoglucemia
Keywords
Aerobic exerciseResistance exercise
Automated Insulin Delivery
Hybrid Closed loop system
Time in range
Hypoglycemia
Spatial coverage (cities)
Bogotá (Colombia)Spatial coverage
ColombiaTemporary coverage
2021Community
Pacientes con Diabetes tipo 1Link to the resource
https://revistaendocrino.org/index.php/rcedm/article/view/721Source
Revista Colombiana de Endocrinología, Diabetes y Metabolismo; Volumen 9 Número 3 , Páginas 328 - 336 (2022)
Google Analytics Statistics