Evaluación de incertidumbres en la técnica de Radioterapia Guiada por Superficie para tratamientos de radiocirugía estereotáctica craneal

dc.contributor.advisorCastellanos López, María Esperanza
dc.contributor.advisorRodríguez Hernández, Andrea Paola
dc.contributor.authorAmaya Ríos, Estefanía
dc.contributor.evaluatorRodríguez Herrera, Wilmar
dc.contributor.evaluatorEstrada Molina, Amilcar
dc.contributor.evaluatorMarín Jimenez, Alejandro
dc.coverage.cityBogotá (Colombia)spa
dc.coverage.departmentCundinamarca (Colombia)spa
dc.coverage.regionBogotá, D.C. (Bogotá, Colombia)spa
dc.coverage.spatialColombiaspa
dc.date.accessioned2023-10-13T19:26:20Z
dc.date.available2023-10-13T19:26:20Z
dc.date.created2023-09-08
dc.description.abstractLa complejidad de los procedimientos y nuevas técnicas de radioterapia, así como la reducción de márgenes de irradiación y aumento de dosis por fracción, hacen que sea necesaria la implementación de tecnologías que reduzcan las incertidumbres en el posicionamiento del paciente. La radioterapia guiada por imagen es una de las técnicas de control de posicionamiento que más se utiliza para validar la ubicación del blanco de tratamiento antes de la entrega de la dosis. Existen otras técnicas novedosas como la radioterapia guiada por superficie que se basa en la reconstrucción 3D y monitorización de la superficie del paciente por medio de un sistema de cámaras ópticas. El objetivo de este trabajo fue evaluar dos sistemas que utilizan principios de funcionamiento diferentes en la verificación del posicionamiento del paciente en radiocirugía estereotáxica craneal. Se realizó el comisionamiento de la técnica de radioterapia guiada por superficie por medio de la realización de pruebas que evaluaron el funcionamiento, conectividad, comunicación, exactitud, precisión y alcance del sistema Identify de Varian. Algunas de estas pruebas se realizaron simultáneamente con el sistema de tomografía computarizada de haz cónico que se encuentra integrado al gantry del acelerador lineal, con el fin de analizar y comparar las respuestas de estos dos equipos. Se utilizó la camilla robótica de seis grados de libertad para realizar desplazamientos conocidos a un maniquí antropomórfico de cabeza para poder evaluar los desplazamientos detectados por los dos sistemas de imágenes. El comisionamiento del Identify se llevó a cabo satisfactoriamente y mostró que el sistema permite detectar desplazamientos a nivel submilimétrico de un área útil para radiocirugía estereotáctica de mínimo 22, 34 y 32 cm en dirección vertical, longitudinal y lateral, respectivamente. Ambos sistemas presentaron buena exactitud siendo la diferencia más grande respecto al valor de referencia de 0.5±0.07 mm y 0.3±0.03° para el Identify y 0.3±0.06 mm y 0.4±0.1° para el otro sistema. Igualmente, la desviación típica de los desplazamientos detectados interfracción fueron menores a 0.05 mm y 0.11° lo cual se encuentra dentro de los valores de tolerancia establecidos para radiocirugía estereotáctica. La prueba de análisis de varianza demostró que la detección de los movimientos de ambos sistemas son comparables con los valores de referencia de la camilla. A partir de lo anterior y de los resultados de la prueba ''end-to-end" en donde se reunieron en un mismo procedimiento todas las variables evaluadas en este estudio, se pudo establecer un flujo de uso de estos dos sistemas de imagen para radiocirugía estereotáctica que asegura el posicionamiento del paciente y del volumen de interés y la monitorización continua de los movimientos inter e intrafracción de la superficie del paciente.spa
dc.description.abstractenglishThe complexity of radiotherapy procedures and new techniques, along with the reduction of irradiation margins and an increase in dose per fraction, makes it necessary to implement technologies that reduce uncertainties in patient positioning. Image-guided radiotherapy is one of the positioning control techniques most commonly used to validate the treatment target's location before dose delivery. There are other innovative techniques, such as surface-guided radiotherapy, which is based on 3D reconstruction and monitoring of the patient's surface using an optical camera system. The aim of this study was to evaluate two systems that utilize different operating principles for verifying patient positioning in cranial stereotactic radiosurgery. Commissioning of the surface-guided radiotherapy technique was performed by conducting tests that assessed the functioning, connectivity, communication, accuracy, precision, and range of the Varian Identify system. Some of these tests were performed simultaneously with the cone-beam computed tomography system integrated into the linear accelerator's gantry, to analyze and compare the responses of these two systems. A robotic six-degree-of-freedom couch was used to introduce known shifts to an anthropomorphic head phantom, enabling the evaluation of displacements detected by both imaging systems. The commissioning of the Identify system was successfully carried out and demonstrated that the system can detect sub-millimeter shifts within a useful area for stereotactic radiosurgery of at least 22 mm, 34 mm, and 32 mm in the vertical, longitudinal, and lateral directions, respectively. Both systems exhibited good accuracy, with the largest difference from the reference value being 0.5 ± 0.07 mm and 0.3 ± 0.03 degrees for the Identify system, and 0.3 ± 0.06 mm and 0.4 ± 0.1 degrees for the other system. Likewise, the typical deviation of detected inter-fraction displacements was less than 0.05 mm and 0.11 degrees, which falls within the established tolerance values for stereotactic radiosurgery. The analysis of variance test demonstrated that the motion detection of both systems is comparable to the couch's reference values. Based on the above and the results of the "end-to-end" test, where all evaluated variables in this study were combined in a single procedure, a workflow for the use of these two imaging systems in stereotactic radiosurgery was established, ensuring patient and target volume positioning, as well as continuous monitoring of inter- and intra-fraction surface movements.spa
dc.description.degreelevelMaestríaspa
dc.description.degreenameMagíster en Física Médicaspa
dc.formatPDFspa
dc.format.mimetypeapplication/pdfspa
dc.identifier.instnameinstname:Pontificia Universidad Javerianaspa
dc.identifier.reponamereponame:Repositorio Institucional - Pontificia Universidad Javerianaspa
dc.identifier.repourlrepourl:https://repository.javeriana.edu.cospa
dc.identifier.urihttp://hdl.handle.net/10554/65553
dc.language.isospaspa
dc.publisherPontificia Universidad Javerianaspa
dc.publisher.facultyFacultad de Cienciasspa
dc.publisher.programMaestría en Física Médicaspa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa
dc.rights.licenceAtribución-NoComercial-SinDerivadas 4.0 Internacional*
dc.rights.localDe acuerdo con la naturaleza del uso concedido, la presente licencia parcial se otorga a título gratuito por el máximo tiempo legal colombiano, con el propósito de que en dicho lapso mi (nuestra) obra sea explotada en las condiciones aquí estipuladas y para los fines indicados, respetando siempre la titularidad de los derechos patrimoniales y morales correspondientes, de acuerdo con los usos honrados, de manera proporcional y justificada a la finalidad perseguida, sin ánimo de lucro ni de comercialización. De manera complementaria, garantizo (garantizamos) en mi (nuestra) calidad de estudiante (s) y por ende autor (es) exclusivo (s), que la Tesis o Trabajo de Grado en cuestión, es producto de mi (nuestra) plena autoría, de mi (nuestro) esfuerzo personal intelectual, como consecuencia de mi (nuestra) creación original particular y, por tanto, soy (somos) el (los) único (s) titular (es) de la misma. Además, aseguro (aseguramos) que no contiene citas, ni transcripciones de otras obras protegidas, por fuera de los límites autorizados por la ley, según los usos honrados, y en proporción a los fines previstos; ni tampoco contempla declaraciones difamatorias contra terceros; respetando el derecho a la imagen, intimidad, buen nombre y demás derechos constitucionales. Adicionalmente, manifiesto (manifestamos) que no se incluyeron expresiones contrarias al orden público ni a las buenas costumbres. En consecuencia, la responsabilidad directa en la elaboración, presentación, investigación y, en general, contenidos de la Tesis o Trabajo de Grado es de mí (nuestro) competencia exclusiva, eximiendo de toda responsabilidad a la Pontifica Universidad Javeriana por tales aspectos. Sin perjuicio de los usos y atribuciones otorgadas en virtud de este documento, continuaré (continuaremos) conservando los correspondientes derechos patrimoniales sin modificación o restricción alguna, puesto que, de acuerdo con la legislación colombiana aplicable, el presente es un acuerdo jurídico que en ningún caso conlleva la enajenación de los derechos patrimoniales derivados del régimen del Derecho de Autor. De conformidad con lo establecido en el artículo 30 de la Ley 23 de 1982 y el artículo 11 de la Decisión Andina 351 de 1993, "Los derechos morales sobre el trabajo son propiedad de los autores", los cuales son irrenunciables, imprescriptibles, inembargables e inalienables. En consecuencia, la Pontificia Universidad Javeriana está en la obligación de RESPETARLOS Y HACERLOS RESPETAR, para lo cual tomará las medidas correspondientes para garantizar su observancia.spa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectRadiocirugía estereotáctica, radioterapia guiada por superficie, radioterapia guiada por imágenes, comisionamientospa
dc.subject.armarcMaestría en física médica - Tesis y disertaciones académicasspa
dc.subject.keywordStereotactic Radiosurgery, Surface-Guided Radiotherapy, Image-Guided Radiotherapy, Commissioningspa
dc.titleEvaluación de incertidumbres en la técnica de Radioterapia Guiada por Superficie para tratamientos de radiocirugía estereotáctica cranealspa
dc.title.englishAssessment of uncertainties in the Surface-Guided Radiotherapy technique for stereotactic cranial radiosurgery.spa
dc.type.coarhttp://purl.org/coar/resource_type/c_bdcc
dc.type.driverinfo:eu-repo/semantics/masterThesis
dc.type.hasversionhttp://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.localTesis/Trabajo de grado - Monografía - Maestríaspa

Archivos

Bloque original
Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Trabajo de grado Estefania Amaya R.pdf
Tamaño:
13.56 MB
Formato:
Adobe Portable Document Format
Descripción:
Trabajo de grado
No hay miniatura disponible
Nombre:
Acta de sustentación.pdf
Tamaño:
464.69 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta de aprobación de los directores
No hay miniatura disponible
Nombre:
Carta_de_autorizacion.pdf
Tamaño:
128.64 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta de autorización de autores
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
2.54 KB
Formato:
Item-specific license agreed upon to submission
Descripción: