Logotipo del repositorio
 

Precisión clínica y numérica de los dispositivos de medición de glucosa capilar disponibles en el plan básico de salud para Colombia

dc.contributor.authorGomez-Medina, Ana Maria
dc.contributor.authorJojoa Jojoa, Ruby Isabel
dc.contributor.authorHenao-Carrillo, Diana Cristina
dc.contributor.authorParra, Darío
dc.contributor.authorMuñoz, Óscar
dc.contributor.authorRubio, Claudia
dc.contributor.authorPineros, Mariana
dc.contributor.corporatenamePontificia Universidad Javeriana. Facultad de Medicina. Departamento de Medicina Interna. Endocrinologíaspa
dc.contributor.corporatenamePontificia Universidad Javeriana. Facultad de Medicina. Departamento de Medicina Interna. Medicina Interna
dc.contributor.javerianateacherGomez-Medina, Ana Maria
dc.contributor.javerianateacherHenao-Carrillo, Diana Cristina
dc.contributor.javerianateacherMuñoz, Óscar
dc.coverage.cityBogotá (Colombia)spa
dc.coverage.spatialColombiaspa
dc.coverage.temporal2019
dc.date.accessioned2023-03-14T12:33:29Z
dc.date.available2023-03-14T12:33:29Z
dc.date.created2022-01-10
dc.description.abstractIntroducción: La glucometría tiene un rol crítico en el tratamiento del paciente tratado con insulina. Factores técnicos y medioambientales afectan significativamente la precisión de los glucómetros. El objetivo es establecer la precisión clínica y numérica de los glucómetros usados en Colombia, comparado con glucemia central. Métodos: Estudio de pruebas diagnósticas. Se evaluaron glucómetros del plan básico de salud (GluNeo, GlucoQuick, Optium Neo, Select Plus y Gluco Quick Diamond Voice). Se incluyeron adultos tratados con bomba de infusión de insulina integrada a sistema de monitoreo continuo. Se clasificaron las muestras en ≥100mg dL y <100 mg/dL. Para glucosa <100 mg/dL se administró un bolo de insulina utilizando la función de bolus wizard. Se evalúo la precisión numérica utilizando la media absoluta de la diferencia relativa (MARD) y la precisión clínica, según la proporción las mediciones en las zonas A+B de la gradilla de Clarke y la gradilla de Parkes (Consensus). Dada la relevancia en la práctica clínica de conocer la precisión de los dispositivos en valores de hipoglucemia (≤70 mg/dL), se realizó un análisis exploratorio de las mediciones obtenidas en este rango. Resultados: Se analizaron 520 mediciones. Todos los dispositivos cumplieron requisitos de precisión para glucosa ≥100 mg/dL. Optium Neo y Gluco Quick Diamond Voice alcanzaron estándares de cumplimiento al combinar todos los niveles de medición de 12.1 % y 13.9 %, respectivamente. La precisión clínica para estos dos dispositivos fue de 98% y >95 % según gradilla Parkes (Consensus) y Clarke, respectivamente. Se evidenció mayor variabilidad de los resultados en el rango ≤70 mg/dL. Conclusiones: La precisión numérica fue adecuada para los dispositivos evaluados para valores de glucosa capilar ≥100 mg/dL y disminuye con valores <100mg/dL. Gluco Quick Diamond Voice y Optium Neo tuvieron adecuada precisión clínica y numérica global.spa
dc.description.abstractenglishIntroduction: Self-Monitoring blood glucose (SMBG) has a critical role in the management of patients treated with insulin. Technical and environmental factors significantly affect the accuracy of glucometers. The objective is to establish the clinical and numerical precision of the glucometers used in Colombia, compared to central blood glucose. Methods: Study of diagnostic tests, glucometers of the basic health plan (GluNeo, GlucoQuick, Optium Neo, Select Plus and Gluco Quick Diamond Voice) were evaluated. Adults treated with an insulin infusion pump integrated with a continuous monitoring system were included. The samples were classified as:>100mg dL,>70 and 100 mg/dL, ?70 mg/dL. For glucose ?100 mg/dL a bolus of insulin was delivered using the bolus wizard feature. The numerical precision was evaluated using the mean absolute relative difference (MARD) and the clinical precision according to the proportion measurements in the zones A + B of Clarke and Parkes (Consensus) error grids. Results: 830 measurements were analyzed. All devices met precision requirements for glucose >100mg / dL. Optium Neo and Gluco Quick Diamond Voice, achieved compliance standards by combining all measurement levels of 12.1% and 13.9%, respectively. The clinical precision for these two devices was 98% and >95% according to the Parkes (Consensus) and Clarke error grids, respectively. Greater variability of the results was evidenced in the range ?70mg/dL. Conclusions: The numerical precision was adequate for the devices evaluated for capillary glucose values >100mg/dL and decreases with values ??<100mg/dL. Gluco Quick Diamond Voice and Optium Neo had adequate global numerical and clinical precision.spa
dc.description.comunidadPacientes con Diabetes mellitusspa
dc.description.esciNospa
dc.description.indexingRevista Internacional - No indexadaspa
dc.description.orcidhttps://orcid.org/0000-0002-8907-3470spa
dc.description.orcidhttps://orcid.org/0000-0002-6071-9178spa
dc.description.orcidhttps://orcid.org/0000-0002-1353-148Xspa
dc.description.orcidhttps://orcid.org/0000-0001-6838-3253spa
dc.description.orcidhttps://orcid.org/0000-0001-5401-0018spa
dc.description.orcidhttps://orcid.org/0000-0001-9572-2804spa
dc.description.orcidhttps://orcid.org/0000-0002-0771-9857spa
dc.formatPDFspa
dc.format.mimetypeapplication/pdfspa
dc.identifierhttps://revistaendocrino.org/index.php/rcedm/article/view/625spa
dc.identifier.doihttps://doi.org/10.53853/encr.8.3.625spa
dc.identifier.instnameinstname:Pontificia Universidad Javerianaspa
dc.identifier.issn2389-9786 / 2805-5853 (Electrónico)spa
dc.identifier.reponamereponame:Repositorio Institucional - Pontificia Universidad Javerianaspa
dc.identifier.repourlrepourl:https://repository.javeriana.edu.cospa
dc.identifier.urihttp://hdl.handle.net/10554/63728
dc.language.isospaspa
dc.relation.citationendpage266spa
dc.relation.citationissue3spa
dc.relation.citationstartpage256spa
dc.relation.citationvolume8spa
dc.relation.ispartofjournalRevista Colombiana de Endocrinología, Diabetes y Metabolismospa
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa
dc.rights.licenceAtribución-NoComercial 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.subjectGlucómetrospa
dc.subjectGlucosa capilarspa
dc.subjectGlucosa séricaspa
dc.subjectPrecisión clínicaspa
dc.subjectPrecisión numéricaspa
dc.subjectDiabetes mellitusspa
dc.subject.keywordBlood glucosespa
dc.subject.keywordBlood glucose accuracyspa
dc.subject.keywordBlood glucose self-monitoringspa
dc.subject.keywordDiabetesspa
dc.titlePrecisión clínica y numérica de los dispositivos de medición de glucosa capilar disponibles en el plan básico de salud para Colombiaspa
dc.title.englishClinical and numerical precision of capillary glucose measurement devices available in the basic health plan for Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_6501spa
dc.type.hasversionhttp://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.localArtículo de revistaspa

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Precisión clínica y numérica de los dispositivosde medición de glucosa capilar disponiblesen el plan básico de salud para Colombia.pdf
Tamaño:
691.01 KB
Formato:
Adobe Portable Document Format
Descripción:
Artículo
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
2.54 KB
Formato:
Item-specific license agreed upon to submission
Descripción: