Logotipo del repositorio
 

Determinación del módulo de Young en aleaciones de cobalto-cromo nuevas y reutilizadas, coladas en centrifuga convencional y por inducción

dc.contributorLaboratories SGD and CITECeng
dc.contributorLaboratorios SGD y CITECspa
dc.contributor.authorFlórez Alvarado, Alejandra; Pontificia Universidad Javeriana
dc.contributor.authorGonzález Marín, Angélica; Pontificia Universidad Javeriana
dc.contributor.authorKim, Hyung Kuk; Pontificia Universidad Javeriana
dc.contributor.authorRomero Mesa, Juan Carlos; Pontificia Universidad Javeriana
dc.contributor.authorHenao Pérez, Daniel; Pontificia Universidad Javeriana
dc.date.accessioned2018-02-24T15:54:09Z
dc.date.accessioned2020-04-15T18:18:16Z
dc.date.available2018-02-24T15:54:09Z
dc.date.available2020-04-15T18:18:16Z
dc.date.created2009-08-13
dc.description.abstractPROPÓSITO: Estudiar las posibles alteraciones de las propiedades mecánicas de aleaciones de cobalto-cromo (módulo de Young), al comparar materiales reciclados y procedimientos de colado, para establecer si estas aleaciones se pueden reutilizar en la elaboración de estructuras para prótesis parcial removible. MÉTODOS: Para este estudio experimental in vitro se tomaron 60 especímenes colados en aleación de Co-Cr en forma de probeta, los cuales se dividieron en 2 grupos, según el tipo de aleación, Wironit L.A® de Bego y Remanium® 800 de Dentaurum. Cada grupo se dividió en 6 subgrupos de 5 especímenes cada uno según el estado del material y la centrífuga empleada en su elaboración: material nuevo en centrífuga por inducción, material 50% nuevo-50% reutilizado en centrífuga por inducción, material reutilizado totalmente en centrífuga por inducción, material nuevo en centrífuga convencional, material 50% nuevo-50% reutilizado en centrífuga convencional, y material reutilizado totalmente en centrífuga convencional. RESULTADOS: El estado del material es el factor que más ocasionó variabilidad en el módulo de Young, siendo el 50% nuevo-50% reutilizado significativamente mayor que los otros dos estados del material, mientras que al comparar el estado nuevo y reutilizado los valores son similares. El módulo de Young se vio menos afectado por el tipo de centrífuga que se utilice en el proceso de colado. El tipo de aleación de cobalto-cromo Wironit® y Remanium® no estuvo asociado de manera significativa a la variación del módulo de Young, a pesar de presentar ciertas diferencias en los porcentajes de los elementos constituyentes de las aleaciones (α=005).spa
dc.description.abstractenglishPURPOSE: Analyze the possible alterations of mechanical properties of cobalt-chromium alloys measured through the Young’s module, when comaring new and/or recycled materials and casting techniques, in order to establish if those alloys can be resued to fabricate removable partial dentures. METHODS: For this experimental in vitro study, 60 specimens casted in Co-Cr alloys were assigned to two groups according to the type of alloy, Bego’s Wironit L.A® and Dentaurum’s Remanium® 800. The two groups were divided into 6 subgroups of 5 specimens each regarding state of the material and type of centrifuge used: new material with induction centrifuge, 50%-new-and-50%-recycled material with induction centrifuge, recycled material with induction centrifuge, new material with conventional centrifuge, 50%-new-and-50%-recycled material with conventional centrifuge, and recycled material with conventional centrifuge. FINDINGS: The state of the material is the factor that was more associated to the variation of the Young’s module, being the 50%-new-and-50%-recylced material that showed the highest variation. When comparing new and used materials, values were similar. Young’s module was less affected by the type of centrifuge used. There was not a significant association between the kind of Co-Cr alloy, Wironit® y Remanium®, and the variation in the Young’s module, in spite of presenting variations in composition (α=005).eng
dc.formatPDFspa
dc.format.mimetypeapplication/pdfspa
dc.identifierhttp://revistas.javeriana.edu.co/index.php/revUnivOdontologica/article/view/534
dc.identifier.issn2027-3444
dc.identifier.issn0120-4319
dc.identifier.urihttp://hdl.handle.net/10554/30719
dc.language.isospa
dc.publisherEditorial Pontificia Universidad Javerianaeng
dc.relation.citationissueUniversitas Odontologica; Vol 27, No 59 (2008): Universitas Odontológicaspa
dc.relation.citationissueUniversitas Odontologica; Vol 27, No 59 (2008): Universitas Odontológicaeng
dc.relation.urihttp://revistas.javeriana.edu.co/index.php/revUnivOdontologica/article/view/534/357
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2spa
dc.rights.licenceAtribución-NoComercial-SinDerivadas 4.0 Internacional*
dc.titleDeterminación del módulo de Young en aleaciones de cobalto-cromo nuevas y reutilizadas, coladas en centrifuga convencional y por inducciónspa
dc.title.englishYoung's module in new and reused cobalt-chromium alloy, cast in conventional centrifuge and by induction machineeng
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.driverinfo:eu-repo/semantics/article
dc.type.hasversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.localArtículo de revistaspa
dc.type.otherArtículo revisado por pares

Archivos