Logotipo del repositorio
 

Implementation of a simple method to measure total umbilical cord length

dc.contributor.authorOlaya Contreras, Mercedes
dc.contributor.authorSilva, J. L.
dc.contributor.authorBernal, Jaime E
dc.contributor.corporatenamePontificia Universidad Javeriana. Facultad de Medicina. Instituto de Genética Humana
dc.contributor.corporatenamePontificia Universidad Javeriana. Facultad de Medicina. Departamento de Patología
dc.contributor.corporatenamePontificia Universidad Javeriana. Facultad de Medicina. Departamento de Ginecología y Obstetricia
dc.date.accessioned2020-03-12T14:37:44Z
dc.date.accessioned2020-04-15T13:33:01Z
dc.date.available2020-03-12T14:37:44Z
dc.date.available2020-04-15T13:33:01Z
dc.date.created2014-09-09
dc.description.abstractenglishUmbilical cord (UC) alterations are involved in fetal and neonatal complications, and even deaths. Abnormal length has been recognized as the most important UC feature linked to unfavorable results. However, how can the UC be accurately measured in cases in which there is an overriding need for intravenous intervention, urgent lab samples or segments for stem cell cultivation? We performed an observational study to describe our UC length measurement method at the San Ignacio University Hospital (HUSI). All HUSI obstetricians and pediatricians accepted the new rapid cord measurement method; no delays were reported for either maternal or neonatal care. In light of the association of abnormal UC length to complications, we recommend that complete UC length data be registered. Our new and rapid method allows for any UC intervention to be performed, while at the same time, providing precise UC length data under all circumstances.spa
dc.description.paginas269-272spa
dc.description.quartilescopusQ3spa
dc.description.tipoarticuloArtículo originalspa
dc.formatPDFspa
dc.format.mimetypeapplication/pdfspa
dc.format.soportePapel / Electrónicospa
dc.identifierhttps://login.ezproxy.javeriana.edu.co/login?url=https://search.ebscohost.com/login.aspx?direct=true&db=a9h&AN=100099111&lang=es&site=eds-livespa
dc.identifier.doihttps://doi.org/10.3233/NPM-14814023spa
dc.identifier.issn18784429 / 19345798 (Electrónico)spa
dc.identifier.urihttp://hdl.handle.net/10554/47578
dc.languagespaspa
dc.rights.licenceAtribución-NoComercial 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.sourceJournal of Neonatal-Perinatal Medicine; Vol. 7 Núm. 4 (2014)spa
dc.subject.keywordUmbilical cordspa
dc.subject.keywordCord accidentspa
dc.subject.keywordFetal thrombotic vasculopathyspa
dc.subject.keywordCongenital anomaliesspa
dc.titleImplementation of a simple method to measure total umbilical cord lengthspa
dc.title.englishImplementation of a simple method to measure total umbilical cord lengthspa
dc.typeinfo:eu-repo/semantics/article
dc.type.hasversionhttp://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.localArtículo de revistaspa

Archivos

Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
document(24).pdf
Tamaño:
133.56 KB
Formato:
Adobe Portable Document Format
Descripción:
Artículo
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
2.54 KB
Formato:
Plain Text
Descripción: